  LM-79 Intensity measurements are luminous intensity (measured in candela) taken from various angles all around an LED light source. It can combine this group of candela values to calculate zonal or total lumens, which may be used to make illuminance predictions within an application. The LM-79 standard is used mainly for measuring light by how it is perceived by the human eye (photometry or photometric measurement). The standard outlines the testing apparatus, procedures, and circumstances it must follow to make precise and repeatable measurements of the amount of light produced by LED goods and the amount of electrical power such products use. Generally, it may break down the testing techniques into two categories: angularly scanned and integrated (also known as goniometer measures) and measurements that use integrating spheres. This standard's very first iteration had the number. LM-79-08, and it was released to the public in the year 2008. The updated version of the sta