How to do LED photometric test with a 3-meter integrating sphere?
LED light output may be measured using a photometric test that incorporates the use of an integrating sphere that is three meters in diameter. The following is an in-depth description of the procedures that must be followed in order to carry out this kind of test:
- Put together the integrating sphere system. An integrating sphere, a photometer, and a spectrophotometer are the standard components of an integrating sphere system. Put together these individual parts in accordance with the directions provided by the manufacturer.
- When installing the LED light within the integrating sphere, make sure that it is positioned so that it is towards the center of the sphere and that it is firmly fastened in place.
- Before beginning the test, perform a calibration on the photometer in accordance with the instructions provided by the manufacturer. This is essential in order to guarantee accurate findings.
- After the LED light has been placed, you must now switch it on and wait for it to reach its maximum level of brightness before proceeding.
- Use the photometer to determine the luminous flux of the LED light. This may be done by measuring the luminous flux. This statistic reflects the total quantity of visible light that the light emits into the surrounding environment.
- Make a note of the findings of the luminous flux measurement performed on the LED light.
- Repeat the procedure: Repeat the procedure for any additional LED lights that are being evaluated, and then compare the findings to figure out which light generates the most light.
- Conduct an analysis of the spectral distribution If you so like, you may make use of the spectrophotometer in order to conduct an analysis of the spectrum distribution of the light that is produced by the LED light. The results of this measurement, which often take the shape of a graph or table, offer information on the color and intensity of the light.
- Determine the efficiency of the LED light If you so wish, you may determine the efficiency of the LED light, which is the quantity of light generated in relation to the amount of energy that is spent. The efficiency is often expressed as a percentage and need to be evaluated in relation to either industry standards or various other LED lights.
In order to get reliable
results, it is essential to check that the integrating sphere system has been
correctly calibrated and is being properly maintained. When using this kind of
equipment, you should always be sure to follow the directions provided by the
manufacturer and take all necessary safety measures.
In order to eliminate as
many potential causes of mistake as possible, it is strongly suggested that the
examination be carried out in a regulated setting. It is necessary to conduct
the test a number of times in order to confirm its repeatability and get an
accurate figure for the luminous flux on average. Documenting and submitting
the findings of the test to the scrutiny of an authority in the area of LED lighting for the purpose of validating their veracity and gaining more
comprehension of the topic is essential.
Comments
Post a Comment