An LED light's light output and spectrum distribution may be measured using a procedure known as a photometric test utilizing a spectrometer integrating sphere system. This test measures the light output. An explanation of each step that must be completed in order to carry out this kind of test is provided below:
- Put together the integrating sphere system. An integrating sphere, a photometer, and a spectrophotometer are the standard components of an integrating sphere system. Put together these individual parts in accordance with the directions provided by the manufacturer.
- When installing the LED light within the integrating sphere, make sure that it is positioned so that it is towards the center of the sphere and that it is firmly fastened in place.
- Perform a calibration on the photometer Before beginning the test, perform a calibration on the photometer in accordance with the instructions provided by the manufacturer. This is essential in order to guarantee accurate findings.
- After the LED light has been placed, you must now switch it on and wait for it to reach its maximum level of brightness before proceeding.
- Use the photometer to determine the luminous flux of the LED light. This may be done by measuring the luminous flux. This statistic reflects the total quantity of visible light that the light emits into the surrounding environment.
- Make a note of the findings of the luminous flux measurement performed on the LED light.
- Use the spectrophotometer to determine the spectral distribution of the light emitted by the LED light. This may be done by measuring the spectral distribution of the light. The results of this measurement, which often take the shape of a graph or table, offer information on the color and intensity of the light.
- Determine the efficiency of the LED light If you so wish, you may determine the efficiency of the LED light, which is the quantity of light generated in relation to the amount of energy that is spent. Efficiency is often expressed as a percentage and need to be evaluated in relation to either industry standards or various other LED lights.
In order to get reliable
results, it is essential to check that the integrating sphere system has been
correctly calibrated and is being properly maintained. When using this kind of
equipment, you should always be sure to follow the directions provided by the
manufacturer and take all necessary safety measures.