Posts

What is a mirror goniophotometer used for?

Image
A mirror goniophotometer is a specialized instrument that is used to measure the amount of light that is emitted by lamps, luminaires, and other types of light sources. The device works by spinning a mirror to gather light from the source, then redirecting that light onto a detector that detects the amount of light present. The instrument is able to measure the light output from a source at a variety of angles, which enables it to ascertain crucial factors such as color temperature, chromaticity coordinates, luminous intensity, and color rendering index (CRI) . In the lighting sector, mirror goniophotometers are often used to analyze and describe the performance of light sources, to compare various products, and to guarantee that light sources fulfill applicable industry standards. They may also be used to conduct tests to assess the quality of light provided by a source and to detect any faults that may hinder performance. Using a mirror goniophotometer has a number of benefits,

How to do street light photometric measurement according to CIE 121 using a goniophotometer?

Image
The process of measuring the light output of street lights and evaluating the data to derive critical characteristics such as luminous intensity, luminous flux, chromaticity coordinates, color temperature, and color rendering index is referred to as street light photometric measurement (CRI). The purpose of this measurement is to guarantee that street lights provide an accurate, consistent, and high-quality amount of light that is in accordance with the standards set by the industry. Position the goniophotometer in an area that is devoid of impediments and is representative of the setting in which the street light is meant to function. Place the street light in the appropriate location on the goniophotometer and check to see that it is secured firmly. Adjust the settings on the goniophotometer to guarantee precise readings by adjusting the settings on the goniophotometer in accordance with the instructions provided by the manufacturer. The goniophotometer should then be positioned a

Type C goniophotometer for LED flood light measurement according to CIE LM standards

Image
A goniophotometer of type C may be used in order to measure LED flood lights in a manner that is compliant with the standards that have been set by the CIE LM (International Commission on Illumination - Photometry). The CIE LM standards provide guidelines for the measurement of the light output of LED flood lights and other kinds of light sources. These standards were developed by the CIE. Because of these criteria, it will be possible to make reliable comparisons between the different light sources in terms of their overall performance. A goniophotometer of type C is used to measure the amount of light that is emitted by LED flood lights. This measurement gives a comprehensive analysis of the many performance characteristics of the lights. After the data have been measured, they are analyzed in order to ascertain critical aspects such as the chromaticity coordinates, color temperature, and color rendering index (CRI). If lighting professionals and manufacturers test LED flood lig

Type C goniophotometer for LED panel light test according to CIE standard

Image
A goniophotometer of type C is a specific sort of goniophotometer that was designed specifically for the purpose of measuring the light that is emitted by LED panels in line with the standards established by the CIE. The International Commission on Illumination, often known as the CIE, is in charge of setting standards for the measurement and evaluation of all types of light sources, including LED panel lights. A type C goniophotometer is furnished with a rotating head that can be positioned at a number of various angles for the purpose of measuring the light output of an LED panel light from a variety of different angles. This is done for the purpose of measuring the light output of an LED panel light. Because of this, it is now able to carry out an in-depth investigation of the light source's capacity to show colors in a consistent manner, in addition to the light source's luminous intensity, color rendering, and other critical characteristics of its performance. In orde

LISUN goniophotometer for LED CIE C-γ test

Image
The CIE C- γ test is a technique for assessing the color performance of illumination sources in accordance with the criteria established by the International Commission on Illumination (CIE). It is also known as the CIE Color General Photometry Test. The test determines whether or not a light source is capable of rendering colors in the same way as the human eye does—that is, appropriately and accurately. The chromaticity coordinates of the light source that is being examined are compared to those of a reference light source that has a chromaticity that is already known. Examples of such reference light sources are a black body radiator and a daylight source. The color rendering index (CRI) of the light source may be determined by taking the difference between the two sets of chromaticity coordinates into consideration. The color rendering index, or CRI, is a numerical measurement that may vary from 0 to 100; generally speaking, higher values indicate improved color rendering abil

LISUN goniophotometer can be used for LED light test according to LM/CIE standards

Image
Yes, the LISUN goniophotometer may be used for the purpose of evaluating LED lighting in compliance with the criteria specified by both LM (Lighting Metrology) and CIE (International Commission on Illumination). A goniophotometer is a specialized instrument that is used for the purpose of determining the luminous intensity of a light source from a range of vantage points. This may be accomplished by measuring the intensity of the light emanating from the light source. A goniophotometer is able to provide a comprehensive investigation of the photometric performance of an LED light. To do this, you will need to spin the LED light while the device measures the amount of light emitted in a variety of different directions. The Illuminating Engineering Society (IES) is the organization that is tasked with establishing the LM standards . These standards provide a description of the minimal requirements for the luminous intensity, chromaticity, and color rendering capabilities of various lig

How to do photometry test for outdoor lights according to CIE 121?

Image
The following procedures are required to complete the photometry test for outdoor lights in accordance with the standard CIE 121 established by the International Commission on Illumination (CIE): Preparation: Collect all the essential tools, such as a photometer, goniometer, and a source of reference light. Make certain that the testing setting is appropriate, with a consistent and well-managed amount of ambient light. Prepare the test sample, which may be anything like an outside light fixture, by making sure that it is correctly placed and in good functioning condition. Calibration: Follow the directions provided by the manufacturer to properly calibrate both the photometer and the goniometer. Check if the measuring equipment is accurate by comparing the results of the measurements you took with the reference light source to the photometric values that are already known about it. Measurement: Position the photometer so that it is a predetermined distance from the s